Thaum lub ntsuas kub viav vias tsis ua haujlwm, tam sim ntawd pib ua peb - cov txheej txheem tuav ib ntus: kev hloov pauv tsis tu ncua, tswj qhov kub thiab txias, thiab kev tiv thaiv ib ntus. Qhov no yog qhov tseem ceeb los tiv thaiv kev cuam tshuam ntawm kev tsim khoom thiab cov khoom tsis xws luag, tshwj xeeb tshaj yog nyob rau hauv qhov siab - qhov kub thiab txias - ib puag ncig ntawm Wuhan qhov chaw teb sai yog qhov tseem ceeb.

 

1. Tsis Siv Neeg / Kev Taw Qhia Hloov mus rau Backup Sensor (Ua tiav hauv 0-30 vib nas this)

Lub kaw lus yuav tsum cia li kuaj pom thawj qhov tsis ua haujlwm (xws li, teeb liab rov qab mus rau xoom, qhov sib txawv ntawm qhov kub thiab txias> 2℃rau 3 vib nas this) thiab hloov mus rau cov channel thaub qab hauv 0.5 vib nas this.

Yog tias tsis siv neeg hloov pauv tsis ua haujlwm, tam sim ntawd yuam kom hloov phau ntawv mus rau lub ntsuas hluav taws xob txhawm rau tiv thaiv qhov kub thiab txias tsis ua haujlwm.

Tom qab hloov pauv, saib seb qhov ntsuas kub nkhaus puas ruaj khov kom paub meej tias cov channel thaub qab ua haujlwm li qub.

 

2. Qhib PID phau ntawv tswj qhov kub thiab txias (hauv 30 vib nas this mus rau 5 feeb). Yog hais tias ob qho tib si thawj thiab thaub qab sensors malfunction los yog switching tsis ua hauj lwm, tam sim ntawd disconnect lub AI them nyiaj system thiab hloov mus rau ib txwm PID tswj. Manually teem lub hom phiaj tus nqi raws li cov txheej txheem keeb kwm tsis tau (xws li, feem ntau siv kub ntawm 280 degree) thiab saib xyuas qhov ntsuas kub hloov pauv. Kev tswj qhov kub thiab txias tuaj yeem txo tau mus rau ± 1.0℃kom ntseeg tau tias cov dej ntws ruaj khov thiab ua kom luv luv - lub sij hawm ntau lawm.

Tus Nqi Ua Haujlwm: Ib lub tuam txhab kho mob tau zam cov khoom seem uas muaj nqis ¥ 120,000 los ntawm kev hloov pauv sai sai rau PID tswj.

 

3. Kev tiv thaiv ib ntus thiab kev saib xyuas ntau lawm (kom txog thaum hloov tiav)

Ua kom lub tswb nrov ib ntus: Ib ntus nce qhov kub ntawm qhov sib txawv ntawm lub tswb rau 3℃kom tiv thaiv cov tswb nrov tsis tshua muaj kev cuam tshuam rau kev tsim khoom;

Enhance Infrared Temperature Comparison: Scan the nozzle's outer surface with an infrared thermometer every 15 minutes. If the deviation from the system reading is >3 degree, tam sim ntawd nres lub tshuab;

Txo Cov Pace Ntau Lawm: Ua kom tsim nyog qeeb ntawm kev txhaj tshuaj molding voj voog kom txo tau cov thermal poob siab thiab tiv thaiv qhov ua txhaum ntawm kev nce ntxiv;

Mark Cov Khoom Uas Tsis Zoo: Ib tus neeg kos cov khoom tsim tawm thaum lub sijhawm tswj kev kub ntxhov rau kev soj ntsuam tag nrho tom qab lossis txo qis.

Cov lus pom zoo hauv cheeb tsam: Thaum lub caij los nag, tso lub pob khoom desiccant rau hauv lub thawv sib txuas thiab tig rau lub tshuab cua sov me me kom tiv thaiv kev nqus noo noo.