Ua kom muaj kev ruaj ntseg ntawm kev ntsuas qhov kub thiab txias yuav tsum muaj plaub- qhov ntev kaw- lub voj voog kev tswj hwm uas suav nrog kev saib xyuas tsis tu ncua, kev tswj ib puag ncig, kev tshuaj ntsuam xyuas ntse, thiab kev saib xyuas tsis tu ncua. Qhov no yog qhov tseem ceeb tshwj xeeb tshaj yog nyob rau hauv siab - qhov kub thiab txias - qhov chaw nyob hauv Wuhan, qhov chaw noo noo thiab kev hloov pauv yuav tsum muaj zog.
1. Kev soj ntsuam cov ntaub ntawv tsis tu ncua rau 72 teev tom qab kho
Lub hauv paus / Thaub qab Kub Qhov Sib txawv ntawm qhov ruaj khov: Tom qab 72 teev ntawm kev soj ntsuam tas li, qhov kub sib txawv ntawm cov thawj thiab thaub qab sensors yuav tsum nco ntsoov<0.5℃. Exceeding this limit will trigger an early warning.
Temperature Curve Smoothness: No glitch, jumps (>5℃/s), or drift (>0.5℃/ h) yuav tsum tshwm sim, ua kom ntseeg tau AI cov nyiaj them poob haujlwm.
AI Weight Dynamic Tracking: The weight of normal points should remain >0.8, thaum cov ntsiab lus txawv txav yuav tsum tau rov pib dua xoom kom tsis txhob muaj kev cuam tshuam tsis raug.
Tus nqi engineering: Ib lub tuam txhab txo qis tus nqi rov qab los ntawm 12% mus rau 2.3% txog 72-teev kev txheeb xyuas qhov tseeb.
2. Kev Tiv Thaiv Ib puag ncig Adaptability (hais txog qhov kev sib tw high humidity hauv Wuhan)
|
Kev ntsuas |
Muaj nuj nqi |
Cov lus pom zoo siv |
|
Nitrogen Purge Nruam Kev Ua Haujlwm |
Isolates noo noo los ntawm kev nkag mus rau hauv qhov kub thiab txias chamber |
Siab tswj ntawm 0.2 ~ 0.4MPa, tshuaj xyuas txhua hnub |
|
Nano Peb -Cov Ntawv Pov Thawj Txheej Re- tshuaj xyuas |
Moisture - pov thawj, ntsev tsuag - pov thawj, mildew - pov thawj |
Txheej kev ncaj ncees txheeb xyuas peb lub hlis twg |
|
Natural Convection Cooling Structure |
Tshem tawm kiv cua tsis ua hauj lwm txaus ntshai |
Disables yuam cua txias, kom 500,000 teev MTBF |
3. Kev Ntsuam Xyuas Kev Txawj Ntse thiab Tus Kheej -Kev Kawm Mechanism (PHM System)
Tiag -Lub Sij Hawm Saib Xyuas Kev Tiv Thaiv: Tshawb xyuas cov kev hloov pauv hauv kev tiv thaiv hluav taws xob, muab 30-hnub ua ntej ceeb toom ntawm kev laus lossis kev sib cuag tsis zoo;
Kev ntsuas kub nce siab: AI qauv txheeb xyuas qhov txawv txav ntawm qhov kub thiab txias, txiav txim siab coking lossis rwb thaiv tsev tsis ua haujlwm;
Dynamic Weight Redistribution: Hloov kho cov ntaub ntawv hnyav raws li kev noj qab haus huv, rov pib qhov hnyav ntawm cov ntsiab lus txawv txav mus rau xoom;
Virtual Measurement Point Self-calibration: Siv LSTM qauv los kwv yees qhov kub thiab txias hauv qhov chaw tsis tau kuaj, txo kev cia siab ntawm lub cev sensors txog li 30%.
Tus nqi tsim nyog: Tom qab siv PHM, lub tuam txhab kho mob txo nws qhov nruab nrab txhua xyoo uas tsis tau npaj tseg los ntawm 187 teev mus rau 29 teev.
4. Tsis tu ncua thiab calibration kaw voj
|
Theem Kho |
Cov ntsiab lus ua haujlwm |
Lub voj voog ua tiav |
Lub hom phiaj ruaj khov |
|
Kev tshuaj xyuas txhua hnub |
Tshawb xyuas cov xaim, nitrogen siab, thiab cov pa roj carbon monoxide |
Rau kev hloov |
Tiv thaiv kom tsis txhob poob siab |
|
Ntxuav txhua hli |
Ntxuav lub nozzle residue nrog isopropanol |
Txhua hli |
Tiv thaiv kom tsis txhob muaj zog thermal |
|
Calibration Peb Hlis |
Hloov kho lub sij hawm tas li siv cov kauj ruam xeem |
TT Ib lub hlis twg |
Khaws AI qauv raug |
|
Hloov Txhua Xyoo |
Hloov siab - poob thermocouples |
Txhua xyoo |
Txuas lub ntsiab tswj chav tsev lifespan |
Cov ntaub ntawv siv: Jiangsu Kangfeite txo cov nqi tsim khoom los ntawm 19% los ntawm cov txheej txheem txheem.

