Yuav ua li cas sib txawv ntawm Teflon-Coated Corrosion-Resistant Thermocouples thiab Kho -Thread Probe-Type Platinum Resistance Thermometers

Jul 29, 2020

Tso lus

Hauv kev ntsuas kub ntawm kev lag luam, Teflon-coated corrosion- tiv taus cov thermocouples thiab ruaj khov- xov sojntsuam- hom platinum tiv thaiv tus pas ntsuas kub yog ob hom kev ntsuas kub. Lawv muaj qhov sib txawv tseem ceeb hauv kev tsim qauv, cov qauv kev ua haujlwm, cov yam ntxwv ntawm kev ua haujlwm, thiab cov xwm txheej ntawm daim ntawv thov. Cov kev sib piv hauv qab no yuav qhia txog lawv qhov sib txawv tseem ceeb.

I. Qhov txawv ntawm cov qauv tsim thiab kev teeb tsa

1. Teflon-Coated Corrosion-Resistant Thermocouple

Lub ntsiab feature ntawm Teflon -coated corrosion- resistant thermocouple nyob rau hauv nws Teflon sheath tiv thaiv thiab bimetallic hlau qauv. Nws feem ntau yog siv Teflon (polytetrafluoroethylene) sheath los qhwv lub raj hlau tiv thaiv, nrog ob txoj hlua hlau sib txawv (xws li npib tsib xee-}chromium thiab npib tsib xee- silicon) welded ua ke sab hauv los ntsuas qhov kawg. Lub Teflon sheath muaj kev ruaj ntseg tshuaj zoo heev thiab tuaj yeem tiv thaiv corrosion los ntawm cov kua qaub uas muaj zog, muaj zog hauv paus, thiab cov kuab tshuaj organic, ua rau nws tsim nyog rau corrosive ib puag ncig xws li cov tshuaj thiab tshuaj industries. Nws txoj kev txhim kho feem ntau yog threaded kev twb kev txuas los yog flange kho, xyuas kom nruj haum nrog cov khoom nto los txhim kho kev ntsuas qhov tseeb thiab cov lus teb ceev. Piv txwv li, nyob rau hauv ib tug tshuaj reactor, lub Teflon sheath tiv thaiv lub thermocouple los ntawm corrosive media, thaum lub threaded kev twb kev txuas tso cai rau kom ceev installation. Nws cov qauv tsim qhia txog kev tiv thaiv corrosion ntawm lub sheath thiab kev ywj pheej ntawm cov xov hlau bimetallic. Teflon sheath txo qhov cuam tshuam ntawm ib puag ncig yam ntawm kev ntsuas qhov tseeb thiab txhim khu kev tiv thaiv rau cov neeg kho tshuab poob siab. Txawm li cas los xij, cov txheej txheem kev teeb tsa yuav tsum ua kom ntseeg tau tias cov sheath nyob rau hauv kev sib cuag nrog qhov chaw ntawm cov khoom raug ntsuas, uas ua rau kom qhov nyuaj ntawm kev teeb tsa, thiab cov xov hlau bimetallic tuaj yeem oxidize nyob rau hauv siab - qhov kub thiab txias ib puag ncig, cuam tshuam ntev - lub sij hawm stability.

2. Tsau -Thread Probe-Type Platinum Resistance Thermometer

Cov yam ntxwv tseem ceeb ntawm qhov ruaj khov- xov sojntsuam- hom platinum tiv thaiv tus pas ntsuas kub nyob hauv nws cov xov txuas ruaj khov thiab platinum hlau winding qauv. Nws feem ntau siv cov xov ruaj khov (xws li M20 × 1.5) kom ua tiav kev teeb tsa ruaj khov los ntawm kev ntsia hlau rau hauv qhov chaw ntawm cov khoom raug ntsuas. Sab hauv, platinum xaim yog qhov txhab ntawm lub ceramic lossis mica thav duab los ua qhov kub thiab txias -sensing element. Cov xov ruaj ruaj tsim kom muaj kev sib txuas ntawm qhov kev sojntsuam thiab cov khoom siv nto, ua rau nws haum rau siab -siab lossis daim ntawv thov uas yuav tsum tau ntsuas ntev ntev -. Piv txwv li, hauv kev ua zaub mov lossis kev lag luam tshuaj, cov xov xov ruaj khov tsim kom ntseeg tau tias qhov kev sojntsuam tseem nyob ruaj khov ntawm - cov kav dej siab, txo qhov cuam tshuam ntawm kev co ntawm kev ntsuas. Nws cov qauv tsim qhia txog kev sib txuas ntawm cov xov hlau kho thiab kev ruaj ntseg ntawm platinum hlau. Cov xov ruaj ruaj tsim txo cov kev cuam tshuam ntawm ib puag ncig ntawm kev ntsuas qhov tseeb thaum txhim kho kev tiv thaiv rau cov neeg kho tshuab poob siab thiab tshuaj lom neeg corrosion. Txawm li cas los xij, cov txheej txheem kev teeb tsa yuav tsum tau ua kom ntseeg tau tias cov xov muaj kev sib cuag nrog lub ntsej muag ntawm cov khoom raug ntsuas, uas ua rau kom qhov nyuaj ntawm kev teeb tsa. Tsis tas li ntawd, kev sib txuas ntawm threaded tej zaum yuav loosen vim kev co thaum lub sij hawm ntev - siv, cuam tshuam rau kev ntsuas qhov tseeb.

II. Qhov txawv ntawm Cov Cai Ua Haujlwm

1. Txoj Cai Ua Haujlwm ntawm Teflon-Coated Anti-Corrosion Thermocouple

Thermocouples yog raws li cov nyhuv Seebeck, qhov twg ob lub hlau conductors sib txawv ua kom muaj qhov sib txawv ntawm qhov sib txawv ntawm qhov kub thiab txias. Thaum ob lub hlau conductors txuas nrog rau tsim ib lub voj voog kaw, thiab ob qhov kev sib txuas muaj qhov sib txawv ntawm qhov kub thiab txias, ib qho hluav taws xob hluav taws xob tsim tawm hauv Circuit Court. Qhov loj ntawm lub zog no muaj feem xyuam rau cov khoom siv thiab qhov kub thiab txias sib txawv ntawm cov junctions. Los ntawm kev ntsuas lub zog electromotive, qhov ntsuas kub tuaj yeem suav tsis ncaj. Thermocouples muaj siab rhiab heev; 1℃qhov kub thiab txias hloov ua rau muaj peev xwm hloov pauv ntawm kwv yees li 5-40 microvolts. Lawv cov qauv yooj yim thiab tsis muaj qhov txav txav ua rau lawv haum rau siab -kub, siab-siab, thiab corrosive ib puag ncig. Qhov sib ntxiv ntawm Teflon txheej ntxiv nthuav dav lawv daim ntawv thov ntau yam, tso cai rau lawv ua haujlwm ruaj khov nyob rau hauv ib puag ncig corrosive heev.

2. Txoj Cai Ua Haujlwm ntawm Kev Tshawb Fawb Cov Xov Tooj Tsau -Type Platinum Resistance Thermometer

Platinum resistance thermometers yog raws li cov yam ntxwv uas cov hlau tsis kam hloov nrog kub. Tus nqi tsis kam muaj qhov tsis yog -txoj kev sib raug zoo nrog kub thiab yuav tsum tau suav nrog cov ntxhuav lossis cov qauv (piv txwv li, Pt100 muaj qhov tsis kam ntawm 100Ω ntawm 0 degree, thiab tus nqi kuj nce linearly nrog nce kub) los txiav txim qhov ntsuas kub. Platinum kuj thermometers muaj siab rhiab heev; 1℃qhov kub thiab txias hloov ua rau muaj kev hloov pauv tseem ceeb hauv cov nqi tiv thaiv. Lawv cov qauv yooj yim thiab tsis muaj qhov txav txav ua rau lawv tsim nyog rau kev ntsuas qhov tseeb ntawm qhov nruab nrab thiab qis qis (-200℃txog 600 degree), tab sis muaj zog sib nqus teb los yog cov neeg kho tshuab vibrations yuav tsum tau zam kom tsis txhob cuam tshuam kev ntsuas qhov tseeb. Txoj hlua ruaj khov tsim tso cai rau lawv tswj kev ntsuas kev ntsuas ruaj khov txawm tias nyob hauv qhov chaw kub kub. III. Kev Qhia Txog Tus Kheej

1. Kev tshuaj xyuas qhov muag

Teflon-sheathed corrosion-resistant thermocouple: Lub taub hau feem ntau yog npog nrog Teflon sheath, thiab sab hauv muaj ob txoj hlua hlau sib txawv welded ua ke. Lub sheath yog dawb los yog pob tshab thiab muaj ib tug du nto.

Tsau - xov sojntsuam- hom platinum tiv thaiv tus pas ntsuas kub: Lub taub hau feem ntau yog npog nrog lub raj hlau tiv thaiv, thiab sab hauv yog qhov kub thiab txias - qhov ntsuas qhov ntsuas tau ua los ntawm platinum hlau. Cov xov ruaj ruaj yog screwed rau saum npoo ntawm cov khoom raug ntsuas.

2. Txoj kev xaim

Teflon-sheathed corrosion{1}}resistant thermocouple: Siv ob- xov hlau (zoo thiab tsis zoo), lub thawv sib txuas yog cim "TC+" thiab "TC-", thiab cov hlau lead feem ntau yog xim liab (zoo) thiab dub / xiav (tsis zoo).

Tsau- xov sojntsuam- hom platinum tiv thaiv tus pas ntsuas kub: Siv peb lub- xov hlau (R1, R2, R3), lub thawv sib txuas yog cim "R1", "R2", "R3", thiab cov hlau lead feem ntau yog xim liab, dawb, thiab daj.

3. Kev ntsuas Multimeter

Teflon-sheathed corrosion{1}}resistant thermocouple: Tus nqi tiv thaiv tsawg heev, feem ntau tsuas yog ob peb ohms.

Tsau - xov sojntsuam- hom platinum tiv thaiv tus pas ntsuas kub: Tus nqi tiv thaiv yog kwv yees li 100 ohms ntawm chav tsev kub (Pt100).

IV. Qhov txawv ntawm Daim Ntawv Thov Scenarios

1. Teflon-cov ntaub thaiv corrosion-resistant thermocouple

Ib puag ncig zoo corrosive: haum rau tshuaj lom neeg, tshuaj, thiab lwm yam lag luam; Teflon sheath tuaj yeem tiv thaiv corrosion los ntawm cov kua qaub muaj zog, muaj zog hauv paus, thiab cov kuab tshuaj organic.

Kev kub siab - ib puag ncig kub: Ua haujlwm ruaj khov hauv siab - ntsuas kub, haum rau siab - cov cuab yeej kub xws li reactors thiab cov kav dej.

2. Tsau - xov sojntsuam- hom platinum tiv thaiv tus pas ntsuas kub

Cov xwm txheej xav tau cov lus teb ceev ceev thiab nyob ze: Piv txwv li, hauv kev ua zaub mov lossis kev lag luam tshuaj, qhov ruaj khov - xov tsim ua kom muaj kev sib cuag tag nrho ntawm qhov kev sojntsuam thiab cov khoom siv saum npoo, txhim kho kev ntsuas qhov tseeb thiab cov lus teb ceev.

Nruab nrab thiab qis- qhov kub thiab txias: Ua tau zoo nyob hauv tsev lossis qis- cov xwm txheej siab, xws li HVAC systems.

V. Cov lus qhia xaiv

1. Kev xaiv Teflon-sheathed corrosion-resistant thermocouple

Ib puag ncig tej yam kev mob: Siv nyob rau hauv scenarios yuav tsum tau ntsuas nyob rau hauv heev corrosive ib puag ncig, zam ib puag ncig uas muaj zog vibration los yog cuam tshuam. Cov kev xav tau ntawm kev txhim kho: Xaiv lub Teflon- sheathed sojntsuam nrog cov kev qhia tshwj xeeb uas haum rau cov khoom siv, ua kom muaj kev sib txuas ruaj ntseg.

2. Xaiv qhov ruaj khov - xov hom platinum tiv thaiv tus pas ntsuas kub

Cov kev xav tau ntawm kev txhim kho: Xaiv ib qho kev sojntsuam nrog cov xov xov ruaj khov uas haum rau cov khoom siv, ua kom muaj kev sib txuas ruaj ntseg.

Ib puag ncig tej yam kev mob: Siv nyob rau hauv cov xwm txheej uas yuav tsum tau ntsuas meej thiab ceev teb ntawm qhov nruab nrab mus rau qhov kub thiab txias, tsis txhob muaj zog sib nqus teb los yog mechanical vibration ib puag ncig.

info-1600-1103

Xa kev nug
Tiv tauj pebyog muaj lus nug

Koj tuaj yeem tiv tauj peb ntawm xov tooj, email lossis online daim ntawv hauv qab no. Peb tus kws tshaj lij yuav tiv tauj koj sai sai.