Yuav ua li cas txiav txim siab yog tias reworked magnesium oxide raws li cov qauv?

May 09, 2026

Tso lus

Kev txiav txim siab seb puas rov ua dua magnesium oxide ua tau raws li cov qauv yuav tsum tau ua pov thawj peb zaug ntawm cov tshuaj muaj pes tsawg leeg, cov qauv ntawm lub cev, thiab cov khoom hluav taws xob. Txoj hauv kev tseem ceeb yog ua raws li HG/T 3928-2012 tus qauv, nrog rau thib peb-kev xeem CNAS thiab kev sim ntawm qhov chaw rau kev ntsuam xyuas dav.

 

1. Chemical Composition Testing (Authoritative Judgment Basis) Cov qauv yuav tsum raug xa mus rau CNAS-cov ntaub ntawv pov thawj rau kev tshuaj xyuas tshuaj. Cov khoom xeem thiab cov qauv tsim nyog yog raws li hauv qab no:

Kev Xeem Yam Txuj Ci Txuj Ci Kev Xeem Txuj Ci

MgO Cov ntsiab lus Ntau dua lossis sib npaug rau 95% Acid-Base Titration

Active Magnesium Oxide Ntau dua los yog sib npaug rau 60% Hydration Method

Hydrochloric Acid Insoluble Matter Tsawg dua los yog sib npaug rau 0.5% Pom thiab Ntsuas Txoj Kev

Cl⁻ Tsawg dua lossis sib npaug rau 0.02% Nyiaj Nitrate Titration Method

SO₄²⁻ Tsawg dua lossis sib npaug rau 0.1% Barium Sulfate Turbidity Method

Poob ntawm Ignition Tsawg dua los yog sib npaug rau 5% 950℃Txoj Kev Nyuaj Siab

Cov Tsev Kawm Ntawv Pom Zoo: Zhongxi Testing, Wuhan Kehai Inspection Co., Ltd. Cov ntawv ceeb toom yuav tsum dais CMA / CNAS cim thiab muaj kev cai lij choj.

 

2. Kev txheeb xyuas lub cev thiab cov qauv (Critical to process control)

Yam Khoom Txais Cov Txheej Txheem Kev Tshawb Fawb

Filling Density 2.8–3.2 g / cm³ Kev ntsuas qhov tseeb tom qab vibration thiab compaction

Grain Recrystallization Grain loj hlob, thaj tsam ntshiab, ntom qauv Metallographic Analysis (Gold Standard)

Internal Structural Integrity Tsis muaj voids, tawm -center cores, los yog tsis sib xws qhov ceev X-ray soj ntsuam (kev daws teeb meem ntau dua los yog sib npaug rau 5μm)

Metallographic tsom xam yog cov txheej txheem tseem ceeb rau kev txiav txim siab seb sintering puas ua tiav, ncaj qha cuam tshuam txog lub xeev sab hauv ntawm cov khoom.

 

3. Kev kuaj xyuas hluav taws xob thiab sealing kev ua tau zoo (Kev ua haujlwm ruaj khov)

Cov khoom kuaj

Txais Cov Qauv

Kev kuaj mob

Txias rwb thaiv tsev Resistance

Ntau dua lossis sib npaug li 500 MΩ

500V DC, RH Tsawg dua lossis sib npaug li 30%

Kub rwb thaiv tsev Resistance

Ntau dua lossis sib npaug li 200 MΩ

Ntsuas hauv 2 vib nas this ntawm lub zog tsis ua haujlwm tom qab 30 feeb ntawm kev ua haujlwm

Withstand voltage kev ua tau zoo

AC 2000V, tsis tawg tom qab 1 feeb

Ib puag ncig ib puag ncig

Huab cua nruj

Tsis muaj dej xau tom qab 30 feeb ntawm 0.3MPa kev ntsuas siab

Kev ntsuas dej hauv qab dej

Kev ntsuas kub yog qhov tseem ceeb, vim nws tuaj yeem txheeb xyuas qhov tsis xws luag xws li "dhau txias tab sis tsis kub."

Txheej txheem txiav txim siab

Ua ntej, ua X-ray thiab density ntsuam xyuas → tsis suav nrog cov qauv tsis zoo;

Tom qab ntawd, ua metallographic tsom xam → paub meej tias cov nplej recrystallization;

Thaum kawg, xa mus rau kev kuaj tshuaj muaj pes tsawg leeg + ua tiav kev ntsuas hluav taws xob → daim ntawv kaw - lub voj pov thawj.

Nws raug nquahu kom coj mus kuaj yam tsawg kawg 3 daim los ntawm txhua pawg, tsim kom muaj cov ntaub ntawv tshwj xeeb coded, thiab ua tiav tag nrho lub neej traceability.

info-1328-915

Xa kev nug
Tiv tauj pebyog muaj lus nug

Koj tuaj yeem tiv tauj peb ntawm xov tooj, email lossis online daim ntawv hauv qab no. Peb tus kws tshaj lij yuav tiv tauj koj sai sai.

Hu rau tam sim no!