Cov txheej txheem rau calibration ntawm RC tsis nyob rau hauv kev txhaj tshuaj molding tshuab muab faib ua ob peb theem tseem ceeb:
I. Ua ntej-theem xa tawm
Tag nrho cov khoom siv kho vajtse- suav nrog lub rooj sib tham hauv kev lag luam, PTP synchronization hloov, thiab RC parameter tau txais module- yuav tsum tau lees paub tias ua haujlwm. Tsis tas li ntawd, cov ntaub ntawv hauv paus ntsiab lus rau txhua lub tshuab yuav tsum tau nkag mus rau hauv MES (Manufacturing Execution System) ua ntej, ua kom tiav cov kev teeb tsa tsis siv neeg xauv cov kev txiav txim siab. Nws yog ib qho tseem ceeb rau kev txheeb xyuas qhov kev sib txuas lus sib txuas ntawm qhov ntsuas kub thiab MES system, kom ntseeg tau tias cov ntaub ntawv upload latency tsawg dua lossis sib npaug li 1 thib ob thiab 100% kev sib txuas lus.
II. Calibration Task Triggering thiab Access Locking Phase
Lub MES system tsim RC calibration cov haujlwm tau txais, raws li cov voj voog ua ntej lossis RC drift xyuas cov ntaub ntawv, thiab xa lawv mus rau kev saib xyuas cov neeg ua haujlwm terminals. Raws li qhov tshwm sim, MES system teeb tsa cov khoom siv kaw lus rau cov khoom siv txhaj tshuaj molding tshuab, uas qhia cov lus qhia tias RC calibration tau ua tiav, yog li txwv tsis pub ua haujlwm. Lub sij hawm nkag mus xauv thiab yog vim li cas rau triggering yog nkag rau hauv cov txheej txheem traceability cov ntaub ntawv.
III. Ntawm -site RC Calibration thiab Data Upload Phase
Cov neeg saib xyuas tuaj txog ntawm -qhov chaw nrog cov cuab yeej ntsuas qhov tsim nyog los ua qhov ntsuas ntsuas ntsuas raws li cov txheej txheem tsim. Tshaj tawm -calibration, tag nrho cov ntaub ntawv khaws tseg- xws li RC capacitance, lim txiav tawm zaus, thiab qhov kub thiab txias hloov pauv- raug xa mus rau MES system los ntawm cov khoom lag luam los yog lub davhlau ya nyob twg. MES system txheeb xyuas qhov ua tiav ntawm cov ntaub ntawv upload thiab ceeb toom rau txhua qhov tsis muaj qhov tseem ceeb, ua kom muaj kev ncaj ncees.
IV. Automatic System Verification thiab Unlocking Phase
MES system ua qhov sib piv ntawm cov ntaub ntawv ntsuas ntsuas nrog cov ntsuas ntsuas ua ntej, ntsuas cov ntsuas suav nrog RC capacitance sib txawv, ripple amplitude, thiab kub hloov pauv. Thaum tag nrho cov txheej txheem tau ua tiav, thiab cov ntaub ntawv ruaj ntseg tau lees paub rau 30 vib nas this, lub kaw lus teeb tsa cov lus txib kom qhib nkag mus rau lub tshuab txhaj tshuaj molding. Thaum lub sijhawm no, lub xauv nrawm ntawm cov tswj vaj huam sib luag raug tshem tawm, tso cai rau lub pob pib tsim khoom kom qhib tau.
V. Anomaly tuav thiab kaw -Loop Archiving Phase
Yog hais tias cov ntaub ntawv calibration tsis ua raws li cov qauv tsim, lub kaw lus khaws cia qhov kev nkag mus rau qhov ntsuas phoo, teeb tsa txoj haujlwm thib ob, thiab ceeb toom cov neeg ua haujlwm saib xyuas los ntawm cov lus ceeb toom. Yog tias cov lus txib qhib tsis tau tom qab peb qhov kev sim, lub kaw lus ua rau ob qho tib si hnov thiab pom lub tswb, nrog rau cov ntawv ceeb toom rau cov neeg ua haujlwm txhawm rau txheeb xyuas kev sib txuas lus ntawm qhov chaw. Tag nrho cov txheej txheem- suav nrog lub sijhawm kaw nkag, cov ntaub ntawv ntsuas qhov ntsuas, ntsuas lub sijhawm, thiab cov lus qhia tus neeg teb xov tooj- tau cia li khaws cia rau kev siv thiab qhia txog kev hloov kho rau yav tom ntej calibration cycles. Tom qab qhib lub kaw lus, lub kaw lus saib xyuas cov ntaub ntawv kub ntau lawm rau 30 feeb kom paub meej tias kev ua haujlwm ruaj khov thiab txheeb xyuas qhov txawv txav hauv RC parameter kev ua haujlwm.